Stress area: 156.67 mm² · Proof load: 130,036 N · Clamp load (75%): 97,527 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 312.1 | 230.2 | 2762.3 | 3182.5 |
| Oiled | 0.15 | 234.1 | 172.7 | 2072.0 | 2387.2 |
| Zinc Plated | 0.18 | 280.9 | 207.2 | 2486.2 | 2864.4 |
| Waxed | 0.1 | 156.0 | 115.1 | 1380.7 | 1590.8 |
| MoS₂ | 0.12 | 187.3 | 138.1 | 1657.7 | 1909.9 |
| Galvanized | 0.25 | 390.1 | 287.7 | 3452.7 | 3977.9 |
Stress area: 167.25 mm² · Proof load: 138,818 N · Clamp load (75%): 104,113 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 333.2 | 245.8 | 2949.1 | 3397.7 |
| Oiled | 0.15 | 249.9 | 184.3 | 2211.8 | 2548.3 |
| Zinc Plated | 0.18 | 299.8 | 221.1 | 2653.5 | 3057.1 |
| Waxed | 0.1 | 166.6 | 122.9 | 1474.5 | 1698.9 |
| MoS₂ | 0.12 | 199.9 | 147.4 | 1769.3 | 2038.4 |
| Galvanized | 0.25 | 416.5 | 307.2 | 3686.3 | 4247.1 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 830 MPa × 156.67 mm² = 97,527 N
Step 2 — Torque (dry): T = 0.20 × 0.0160 m × 97,527 N = 312.1 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
Structural steel (equivalent to ASTM A490), heavy machinery, high-strength critical joints, pressure vessels