Stress area: 0.1419 in² · Proof load: 17,028 lbs · Clamp load (75%): 12,771 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 106.4 | 144.3 | 1277.1 | 1471.4 |
| Oiled | 0.15 | 79.8 | 108.2 | 957.8 | 1103.5 |
| Zinc Plated | 0.18 | 95.8 | 129.9 | 1149.4 | 1324.2 |
| Waxed | 0.1 | 53.2 | 72.1 | 638.6 | 735.7 |
| MoS₂ | 0.12 | 63.9 | 86.6 | 766.3 | 882.8 |
| Galvanized | 0.25 | 133.0 | 180.3 | 1596.4 | 1839.2 |
Stress area: 0.1599 in² · Proof load: 19,188 lbs · Clamp load (75%): 14,391 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 119.9 | 162.6 | 1439.1 | 1658.0 |
| Oiled | 0.15 | 89.9 | 121.9 | 1079.3 | 1243.5 |
| Zinc Plated | 0.18 | 107.9 | 146.3 | 1295.2 | 1492.2 |
| Waxed | 0.1 | 60.0 | 81.3 | 719.5 | 829.0 |
| MoS₂ | 0.12 | 72.0 | 97.6 | 863.5 | 994.8 |
| Galvanized | 0.25 | 149.9 | 203.2 | 1798.9 | 2072.5 |
UNC thread, ft·lbs. Values from the table above.
Same bolt, same target clamp load: thread friction alone moves the required torque from 53.2 ft·lbs (waxed) to 133.0 ft·lbs (hot-dip galvanized), 2.5× as much. Match the row to the fastener's actual finish and lubrication.
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 120,000 psi × 0.1419 in² = 12,771 lbs
Step 2 — Torque (dry): T = 0.20 × 0.5 in × 12,771 lbs ÷ 12 = 106.4 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. Typical K-factor, consistent with VDI 2230 friction values.
High-strength applications, heavy equipment, critical joints, suspension components, trailer hitches. Equivalent to ISO 10.9.