Stress area: 693.55 mm² · Proof load: 575,646 N · Clamp load (75%): 431,735 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 2849.5 | 2101.7 | 25220.2 | 29056.9 |
| Oiled | 0.15 | 2137.1 | 1576.2 | 18914.9 | 21792.4 |
| Zinc Plated | 0.18 | 2564.5 | 1891.5 | 22697.7 | 26150.7 |
| Waxed | 0.1 | 1424.7 | 1050.8 | 12609.7 | 14528.0 |
| MoS₂ | 0.12 | 1709.7 | 1261.0 | 15132.1 | 17434.2 |
| Galvanized | 0.25 | 3561.8 | 2627.0 | 31524.6 | 36320.4 |
Stress area: 760.85 mm² · Proof load: 631,506 N · Clamp load (75%): 473,629 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 3126.0 | 2305.6 | 27667.4 | 31876.4 |
| Oiled | 0.15 | 2344.5 | 1729.2 | 20750.6 | 23907.3 |
| Zinc Plated | 0.18 | 2813.4 | 2075.1 | 24900.7 | 28688.8 |
| Waxed | 0.1 | 1563.0 | 1152.8 | 13833.7 | 15938.2 |
| MoS₂ | 0.12 | 1875.6 | 1383.4 | 16600.5 | 19125.9 |
| Galvanized | 0.25 | 3907.4 | 2881.9 | 34583.4 | 39844.5 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 830 MPa × 693.55 mm² = 431,735 N
Step 2 — Torque (dry): T = 0.20 × 0.0330 m × 431,735 N = 2849.5 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
Structural steel (equivalent to ASTM A490), heavy machinery, high-strength critical joints, pressure vessels