Stress area: 1120.9 mm² · Proof load: 425,942 N · Clamp load (75%): 319,456 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 2683.4 | 1979.2 | 23750.1 | 27363.2 |
| Oiled | 0.15 | 2012.6 | 1484.4 | 17813.0 | 20522.9 |
| Zinc Plated | 0.18 | 2415.1 | 1781.3 | 21375.4 | 24627.3 |
| Waxed | 0.1 | 1341.7 | 989.6 | 11875.1 | 13681.6 |
| MoS₂ | 0.12 | 1610.1 | 1187.5 | 14250.6 | 16418.5 |
| Galvanized | 0.25 | 3354.3 | 2474.0 | 29688.1 | 34204.5 |
Stress area: 1205.7 mm² · Proof load: 458,166 N · Clamp load (75%): 343,624 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 2886.4 | 2128.9 | 25546.8 | 29433.2 |
| Oiled | 0.15 | 2164.8 | 1596.7 | 19160.1 | 22074.9 |
| Zinc Plated | 0.18 | 2597.8 | 1916.0 | 22992.5 | 26490.3 |
| Waxed | 0.1 | 1443.2 | 1064.4 | 12773.4 | 14716.6 |
| MoS₂ | 0.12 | 1731.9 | 1277.4 | 15328.6 | 17660.5 |
| Galvanized | 0.25 | 3608.1 | 2661.2 | 31934.4 | 36792.5 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 380 MPa × 1120.9 mm² = 319,456 N
Step 2 — Torque (dry): T = 0.20 × 0.0420 m × 319,456 N = 2683.4 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
General industrial fastening, equipment mounting, moderate structural loads