Stress area: 1120.9 mm² · Proof load: 493,196 N · Clamp load (75%): 369,897 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 3107.1 | 2291.7 | 27500.2 | 31683.7 |
| Oiled | 0.15 | 2330.4 | 1718.8 | 20625.8 | 23763.6 |
| Zinc Plated | 0.18 | 2796.4 | 2062.5 | 24750.2 | 28515.5 |
| Waxed | 0.1 | 1553.6 | 1145.9 | 13750.5 | 15842.4 |
| MoS₂ | 0.12 | 1864.3 | 1375.0 | 16500.5 | 19010.6 |
| Galvanized | 0.25 | 3883.9 | 2864.6 | 34375.4 | 39604.9 |
Stress area: 1205.7 mm² · Proof load: 530,508 N · Clamp load (75%): 397,881 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 3342.2 | 2465.1 | 29581.0 | 34081.1 |
| Oiled | 0.15 | 2506.7 | 1848.8 | 22186.2 | 25561.3 |
| Zinc Plated | 0.18 | 3008.0 | 2218.6 | 26623.1 | 30673.2 |
| Waxed | 0.1 | 1671.1 | 1232.5 | 14790.5 | 17040.5 |
| MoS₂ | 0.12 | 2005.3 | 1479.0 | 17748.4 | 20448.4 |
| Galvanized | 0.25 | 4177.8 | 3081.4 | 36976.7 | 42601.9 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 440 MPa × 1120.9 mm² = 369,897 N
Step 2 — Torque (dry): T = 0.20 × 0.0420 m × 369,897 N = 3107.1 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
Industrial machinery, agricultural equipment, elevated load requirements