Stress area: 1306.09 mm² · Proof load: 365,705 N · Clamp load (75%): 274,279 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 2468.5 | 1820.7 | 21848.1 | 25171.8 |
| Oiled | 0.15 | 1851.4 | 1365.5 | 16386.3 | 18879.1 |
| Zinc Plated | 0.18 | 2221.7 | 1638.6 | 19663.7 | 22655.1 |
| Waxed | 0.1 | 1234.3 | 910.4 | 10924.5 | 12586.4 |
| MoS₂ | 0.12 | 1481.1 | 1092.4 | 13108.8 | 15103.1 |
| Galvanized | 0.25 | 3085.6 | 2275.8 | 27309.9 | 31464.5 |
Stress area: 1397.15 mm² · Proof load: 391,202 N · Clamp load (75%): 293,402 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 2640.6 | 1947.6 | 23371.3 | 26926.7 |
| Oiled | 0.15 | 1980.5 | 1460.7 | 17528.9 | 20195.6 |
| Zinc Plated | 0.18 | 2376.6 | 1752.9 | 21034.7 | 24234.7 |
| Waxed | 0.1 | 1320.3 | 973.8 | 11685.6 | 13463.4 |
| MoS₂ | 0.12 | 1584.4 | 1168.6 | 14023.1 | 16156.4 |
| Galvanized | 0.25 | 3300.8 | 2434.5 | 29214.6 | 33658.9 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 280 MPa × 1306.09 mm² = 274,279 N
Step 2 — Torque (dry): T = 0.20 × 0.0450 m × 274,279 N = 2468.5 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
Moderate-duty industrial applications, machinery guards, medium-strength connections