Stress area: 352.5 mm² · Proof load: 155,100 N · Clamp load (75%): 116,325 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 558.4 | 411.9 | 4942.3 | 5694.1 |
| Oiled | 0.15 | 418.8 | 308.9 | 3706.7 | 4270.6 |
| Zinc Plated | 0.18 | 502.5 | 370.6 | 4447.5 | 5124.1 |
| Waxed | 0.1 | 279.2 | 205.9 | 2471.1 | 2847.1 |
| MoS₂ | 0.12 | 335.0 | 247.1 | 2965.0 | 3416.1 |
| Galvanized | 0.25 | 698.0 | 514.8 | 6177.8 | 7117.6 |
Stress area: 384.42 mm² · Proof load: 169,145 N · Clamp load (75%): 126,859 N
| Surface Condition | K Factor | N·m | ft·lbs | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 608.9 | 449.1 | 5389.2 | 6209.1 |
| Oiled | 0.15 | 456.7 | 336.8 | 4042.1 | 4657.1 |
| Zinc Plated | 0.18 | 548.0 | 404.2 | 4850.2 | 5588.1 |
| Waxed | 0.1 | 304.5 | 224.6 | 2695.1 | 3105.0 |
| MoS₂ | 0.12 | 365.4 | 269.5 | 3234.1 | 3726.1 |
| Galvanized | 0.25 | 761.2 | 561.4 | 6737.2 | 7762.1 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 440 MPa × 352.5 mm² = 116,325 N
Step 2 — Torque (dry): T = 0.20 × 0.0240 m × 116,325 N = 558.4 N·m
Proof stress per ISO 898-1:2013 Table 4. Stress area per ISO 898-1 Annex A. K-factor per VDI 2230.
Industrial machinery, agricultural equipment, elevated load requirements