Stress area: 1.405 in² · Proof load: 46,365 lbs · Clamp load (75%): 34,774 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 869.4 | 1178.7 | 10432.1 | 12019.1 |
| Oiled | 0.15 | 652.0 | 884.0 | 7824.1 | 9014.3 |
| Zinc Plated | 0.18 | 782.4 | 1060.8 | 9388.9 | 10817.2 |
| Waxed | 0.1 | 434.7 | 589.4 | 5216.1 | 6009.6 |
| MoS₂ | 0.12 | 521.6 | 707.2 | 6259.3 | 7211.5 |
| Galvanized | 0.25 | 1086.7 | 1473.4 | 13040.2 | 15023.9 |
Stress area: 1.581 in² · Proof load: 52,173 lbs · Clamp load (75%): 39,130 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 978.3 | 1326.4 | 11738.9 | 13524.7 |
| Oiled | 0.15 | 733.7 | 994.8 | 8804.2 | 10143.5 |
| Zinc Plated | 0.18 | 880.4 | 1193.7 | 10565.0 | 12172.2 |
| Waxed | 0.1 | 489.1 | 663.1 | 5869.5 | 6762.4 |
| MoS₂ | 0.12 | 586.9 | 795.7 | 7043.4 | 8114.8 |
| Galvanized | 0.25 | 1222.8 | 1657.9 | 14673.7 | 16905.9 |
UNC thread, ft·lbs. Values from the table above.
Same bolt, same target clamp load: thread friction alone moves the required torque from 434.7 ft·lbs (waxed) to 1086.7 ft·lbs (hot-dip galvanized), 2.5× as much. Match the row to the fastener's actual finish and lubrication.
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 33,000 psi × 1.405 in² = 34,774 lbs
Step 2 — Torque (dry): T = 0.20 × 1.5 in × 34,774 lbs ÷ 12 = 869.3 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. Typical K-factor, consistent with VDI 2230 friction values.
Large general-purpose bolts, same grade but reduced strength at larger diameters