Stress area: 0.0775 in² · Proof load: 4,262 lbs · Clamp load (75%): 3,197 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 20.0 | 27.1 | 239.8 | 276.2 |
| Oiled | 0.15 | 15.0 | 20.3 | 179.8 | 207.2 |
| Zinc Plated | 0.18 | 18.0 | 24.4 | 215.8 | 248.6 |
| Waxed | 0.1 | 10.0 | 13.6 | 119.9 | 138.1 |
| MoS₂ | 0.12 | 12.0 | 16.3 | 143.9 | 165.7 |
| Galvanized | 0.25 | 25.0 | 33.9 | 299.7 | 345.3 |
Stress area: 0.0878 in² · Proof load: 4,829 lbs · Clamp load (75%): 3,622 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 22.6 | 30.6 | 271.6 | 313.0 |
| Oiled | 0.15 | 17.0 | 23.0 | 203.7 | 234.7 |
| Zinc Plated | 0.18 | 20.4 | 27.7 | 244.5 | 281.7 |
| Waxed | 0.1 | 11.3 | 15.3 | 135.8 | 156.5 |
| MoS₂ | 0.12 | 13.6 | 18.4 | 163.0 | 187.8 |
| Galvanized | 0.25 | 28.3 | 38.4 | 339.5 | 391.2 |
UNC thread, ft·lbs. Values from the table above.
Same bolt, same target clamp load: thread friction alone moves the required torque from 10.0 ft·lbs (waxed) to 25.0 ft·lbs (hot-dip galvanized), 2.5× as much. Match the row to the fastener's actual finish and lubrication.
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 55,000 psi × 0.0775 in² = 3,197 lbs
Step 2 — Torque (dry): T = 0.20 × 0.375 in × 3,197 lbs ÷ 12 = 20.0 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. Typical K-factor, consistent with VDI 2230 friction values.
General-purpose, non-critical bolting. Most common ungraded hardware-store bolts.