Stress area: 0.334 in² · Proof load: 18,370 lbs · Clamp load (75%): 13,778 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 172.2 | 233.5 | 2066.6 | 2381.0 |
| Oiled | 0.15 | 129.2 | 175.2 | 1550.0 | 1785.8 |
| Zinc Plated | 0.18 | 155.0 | 210.2 | 1860.0 | 2142.9 |
| Waxed | 0.1 | 86.1 | 116.7 | 1033.3 | 1190.5 |
| MoS₂ | 0.12 | 103.3 | 140.1 | 1240.0 | 1428.6 |
| Galvanized | 0.25 | 215.3 | 291.9 | 2583.3 | 2976.3 |
Stress area: 0.373 in² · Proof load: 20,515 lbs · Clamp load (75%): 15,386 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 192.3 | 260.7 | 2307.9 | 2659.0 |
| Oiled | 0.15 | 144.2 | 195.5 | 1731.0 | 1994.3 |
| Zinc Plated | 0.18 | 173.1 | 234.7 | 2077.1 | 2393.1 |
| Waxed | 0.1 | 96.2 | 130.4 | 1154.0 | 1329.5 |
| MoS₂ | 0.12 | 115.4 | 156.5 | 1384.8 | 1595.4 |
| Galvanized | 0.25 | 240.4 | 325.9 | 2884.9 | 3323.8 |
UNC thread, ft·lbs. Values from the table above.
Same bolt, same target clamp load: thread friction alone moves the required torque from 86.1 ft·lbs (waxed) to 215.3 ft·lbs (hot-dip galvanized), 2.5× as much. Match the row to the fastener's actual finish and lubrication.
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 55,000 psi × 0.334 in² = 13,778 lbs
Step 2 — Torque (dry): T = 0.20 × 0.75 in × 13,778 lbs ÷ 12 = 172.2 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. Typical K-factor, consistent with VDI 2230 friction values.
General-purpose, non-critical bolting. Most common ungraded hardware-store bolts.