Stress area: 0.1419 in² · Proof load: 7,804 lbs · Clamp load (75%): 5,853 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 48.8 | 66.2 | 585.6 | 675.1 |
| Oiled | 0.15 | 36.6 | 49.6 | 439.2 | 505.8 |
| Zinc Plated | 0.18 | 43.9 | 59.5 | 526.8 | 606.7 |
| Waxed | 0.1 | 24.4 | 33.1 | 292.8 | 337.5 |
| MoS₂ | 0.12 | 29.3 | 39.7 | 351.6 | 404.8 |
| Galvanized | 0.25 | 61.0 | 82.7 | 732.0 | 843.3 |
Stress area: 0.1599 in² · Proof load: 8,794 lbs · Clamp load (75%): 6,596 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 55.0 | 74.6 | 660.0 | 760.7 |
| Oiled | 0.15 | 41.2 | 55.9 | 494.4 | 570.0 |
| Zinc Plated | 0.18 | 49.5 | 67.1 | 594.0 | 684.2 |
| Waxed | 0.1 | 27.5 | 37.3 | 330.0 | 380.4 |
| MoS₂ | 0.12 | 33.0 | 44.7 | 396.0 | 455.8 |
| Galvanized | 0.25 | 68.7 | 93.1 | 824.4 | 949.4 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 55,000 psi × 0.1419 in² = 5,853 lbs
Step 2 — Torque (dry): T = 0.20 × 0.5 in × 5,853 lbs ÷ 12 = 48.8 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. K-factor per VDI 2230.
General-purpose, non-critical bolting. Most common ungraded hardware-store bolts.