Stress area: 0.1063 in² · Proof load: 5,846 lbs · Clamp load (75%): 4,385 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 32.0 | 43.4 | 384.0 | 442.6 |
| Oiled | 0.15 | 24.0 | 32.5 | 288.0 | 331.4 |
| Zinc Plated | 0.18 | 28.8 | 39.0 | 345.6 | 397.7 |
| Waxed | 0.1 | 16.0 | 21.7 | 192.0 | 221.3 |
| MoS₂ | 0.12 | 19.2 | 26.0 | 230.4 | 265.1 |
| Galvanized | 0.25 | 40.0 | 54.2 | 480.0 | 552.7 |
Stress area: 0.1187 in² · Proof load: 6,528 lbs · Clamp load (75%): 4,896 lbs
| Surface Condition | K Factor | ft·lbs | N·m | in·lbs | kgf·cm |
|---|---|---|---|---|---|
| Plain/Dry | 0.2 | 35.7 | 48.4 | 428.4 | 493.5 |
| Oiled | 0.15 | 26.8 | 36.3 | 321.6 | 370.2 |
| Zinc Plated | 0.18 | 32.1 | 43.5 | 385.2 | 443.6 |
| Waxed | 0.1 | 17.9 | 24.3 | 214.8 | 247.8 |
| MoS₂ | 0.12 | 21.4 | 29.0 | 256.8 | 295.7 |
| Galvanized | 0.25 | 44.6 | 60.5 | 535.2 | 616.9 |
Formula: T = K × D × F
Step 1 — Clamp load: F = 0.75 × 55,000 psi × 0.1063 in² = 4,385 lbs
Step 2 — Torque (dry): T = 0.20 × 0.4375 in × 4,385 lbs ÷ 12 = 32.0 ft·lbs
Proof stress per SAE J429 Table 3. Stress area per ASME B1.1. K-factor per VDI 2230.
General-purpose, non-critical bolting. Most common ungraded hardware-store bolts.